Failure analysis of hard disk drive components
A new electrical tagging pattern, which applies a non-return-to zero scheme to directly translate the channel bits to magnetic transitions during the writing of the magnetic pattern around the defect is used. With the help of Kerr magneto-effect, the defective sector is effectively located for furth...