Note: Hybrid-π model and parameter extraction method for electrode-electrolyte interface characterization with superbly accurate reactance
This paper presents an equivalent circuit model for the electrode-electrolyte interface and aims at improving the modeling accuracy of the parasitic effects at frequencies up to 300 MHz. Different from the conventional model, the electrode inductances, body loss capacitances, and body loss resistanc...