Flow-field mitigation of membrane fouling (FMMF) via manipulation of the convective flow in cross-flow membrane applications
Membrane fouling by particulates is largely driven by permeate drag that causes the foulants to move towards the membrane. Cross-flow is used to induce shear at the membrane surface to mitigate the fouling. This study describes the flow-field mitigation of membrane fouling (FMMF) technique that redu...