ROTATING-DISK ELECTRODES - SINGLE-POTENTIAL AND DOUBLE-POTENTIAL STEP CHRONOAMPEROMETRY AND THE ECE-DISP1 PROBLEM

The shape and nature of the chronoamperometric transients resulting from double-potential steps at rotating-disc electrodes, when the electrode reaction is of the ECE or DISP1 type, have been considered. It has been shown that such measurements can provide a clear discrimination between these two me...

Full description

Bibliographic Details
Main Authors: Compton, R, Mason, D, Unwin, P
Format: Journal article
Language:English
Published: 1988