Effect of static load on matrix synthesis rates in the intervertebral disc measured in vitro by a new perfusion technique.
The effect of static loading on matrix synthesis was measured in intact bovine coccygeal discs. The discs were maintained at 37 degrees C in a humid atmosphere and were perfused across their upper and lower surfaces for as long as 8 hours with media containing radioisotopes (3H-proline and 35S-sulph...
Prif Awduron: | Ohshima, H, Urban, J, Bergel, D |
---|---|
Fformat: | Journal article |
Iaith: | English |
Cyhoeddwyd: |
Raven Press Ltd
1995
|
Eitemau Tebyg
-
In vitro method for measuring synthesis rates in the intervertebral disc.
gan: Bayliss, M, et al.
Cyhoeddwyd: (1986) -
The effect of lactate and pH on proteoglycan and protein synthesis rates in the intervertebral disc.
gan: Ohshima, H, et al.
Cyhoeddwyd: (1992) -
Swelling of the intervertebral disc in vitro.
gan: Urban, J, et al.
Cyhoeddwyd: (1981) -
MEASUREMENTS OF HYDROGEN AND OXYGEN IN ISOLATED BOVINE INTERVERTEBRAL DISC
gan: Bartels, E, et al.
Cyhoeddwyd: (1995) -
A 20S APPLICATION OF PHYSIOLOGICAL LEVELS OF HYDROSTATIC-PRESSURE CAN STIMULATE MATRIX SYNTHESIS IN SOME REGIONS OF THE BOVINE INTERVERTEBRAL DISC IN-VITRO
gan: Ishihara, H, et al.
Cyhoeddwyd: (1993)