In situ mechanical testing of nuclear graphite at elevated temperatures: Synchrotron x-ray tomography, neutron diffraction and Raman scattering

High temperature in situ tests of Gilsocarbon polygranular nuclear graphite have investigated the microstructure's deformation at two length scales. At the µm-scale, in situ bending tests observed by synchrotron radiation x-ray computed micro-tomography evaluated the bulk mechanical properties...

Full description

Bibliographic Details
Main Authors: Liu, D, Gludovatz, B, Barnard, H, Kabra, S, Marrow, J, Kuball, M, Ritchie, R