Heat transfer measurements to a gas turbine cooling passage with inclined ribs
The local heat transfer coefficient distribution over all four walls of a large-scale model of a gas turbine cooling passage have been measured in great detail. A new method of determining the heat transfer coefficient to the rib surface has been developed and the contribution of the rib, at 5 perce...
Main Authors: | , , , |
---|---|
Format: | Journal article |
Language: | English |
Published: |
1998
|