Study of double-wall effusion cooling scheme for gas turbine blade applications

<p>Porous multi-wall cooling schemes such as double-wall cooling combined with effusion cooling offer a practical approximation to transpiration cooling which in turn present a potential for high cooling effectiveness. Most of the existing double-wall effusion cooling studies have been on flat...

Full description

Bibliographic Details
Main Author: Ngetich, GC
Other Authors: Ireland, PT
Format: Thesis
Language:English
Published: 2019