Characterization of 1600 Hamamatsu 16-anode photomultipliers for the MINOS Far detector
We are reporting results of the characterization of over 1600 multi-anode R5900-00-M16 photomultipliers manufactured by Hamamatsu Photonics K.K., and installed in the MINOS Far detector. We have conducted extensive tests of the uniformity of gain and collection efficiency of individual anodes, the c...
Główni autorzy: | Lang, K, Day, J, Ellerts, S, Fuqua, S, Guillen, A, Kordosky, M, Lang, M, Liu, J, Opaska, W, Proga, M, Vahle, P, Winbow, A, Drake, G, Thomas, J, Andreopoulos, C, Saoulidou, N, Stamoulis, P, Tzanakos, G, Zois, M, Weber, A, Michael, D |
---|---|
Format: | Journal article |
Język: | English |
Wydane: |
2005
|
Podobne zapisy
-
Study on 3-inch Hamamatsu photomultipliers
od: Giordano Valentina, i wsp.
Wydane: (2016-01-01) -
Performance of Hamamatsu 64-anode photomultipliers for use with wavelength - shifting optical fibres
od: Tagg, N, i wsp.
Wydane: (2005) -
A comprehensive characterization of Hamamatsu 16-and 64-anode PMTs
od: Lang, K, i wsp.
Wydane: (2001) -
Investigating the time properties of an improved 3" Hamamatsu photomultiplier for the KM3NeT Neutrino Telescope
od: Simonelli Andreino, i wsp.
Wydane: (2023-01-01) -
The MINOS calibration detector
od: Adamson, P, i wsp.
Wydane: (2006)