Effect of thermocouple size on the measurement of exhaust gas temperature in internal combustion engines

Accurate measurement of exhaust gas temperature in internal combustion engines is essential for a wide variety of monitoring and design purposes. Typically these measurements are made with thermocouples, which may vary in size from 0.05 mm (for fast response applications) to a few millimetres. In th...

Full description

Bibliographic Details
Main Authors: Papaioannou, N, Leach, F, Davy, M
Format: Conference item
Published: SAE International 2018