Effect of thermocouple size on the measurement of exhaust gas temperature in internal combustion engines
Accurate measurement of exhaust gas temperature in internal combustion engines is essential for a wide variety of monitoring and design purposes. Typically these measurements are made with thermocouples, which may vary in size from 0.05 mm (for fast response applications) to a few millimetres. In th...
Main Authors: | Papaioannou, N, Leach, F, Davy, M |
---|---|
Format: | Conference item |
Published: |
SAE International
2018
|
Similar Items
-
Improving the uncertainty of exhaust gas temperature measurements in internal combustion engines
by: Papaioannou, N, et al.
Published: (2020) -
An optical method for measuring exhaust gas pressure from an internal combustion engine at high speed
by: Leach, F, et al.
Published: (2017) -
Instantaneous exhaust temperature measurements using thermocouple compensation techniques
by: Kar, K, et al.
Published: (2004) -
Influence of surrounding gas temperature on thermocouple measurement
by: Budong Liu, et al.
Published: (2020-06-01) -
Temperature measurement thermocouples
by: 11585 American National Standards Institute