Experimental and numerical investigation of annular casing impingement arrays for faster casing response
The Transient Heat Transfer Facility was developed to test fullscale high pressure compressor and turbine casing air systems using gas turbine engine representative secondary air system conditions. Transient casing response together with blade and disc responses governs achievable tip clearances in...