Do dual-mobility cups reduce revision risk in femoral neck fractures compared with conventional tha designs? An international meta-analysis of arthroplasty registries

<p><strong>Background: </strong>Dual-mobility cups in THA were designed to reduce prosthesis instability and the subsequent risk of revision surgery in high-risk patients, such as those with hip fractures. However, there are limited data from clinical studies reporting a revision b...

Full description

Bibliographic Details
Main Authors: Farey, JE, Masters, J, Cuthbert, AR, Iversen, P, van Steenbergen, LN, Prentice, HA, Adie, S, Sayers, A, Whitehouse, MR, Paxton, EW, Costa, ML, Overgaard, S, Rogmark, C, Rolfson, O, Harris, IA
Format: Journal article
Language:English
Published: Lippincott, Williams and Wilkins 2022