Controlled initiation of short fatigue cracks in 316L steel

Validation of models for short crack behavior requires accurate measurement of crack opening displacement and crack tip strain fields. Development of reliable measurement procedures, using new techniques such as Image Correlation (IC), requires specimens containing cracks with a well defined geometr...

Full description

Bibliographic Details
Main Authors: Stefanescu, D, Marrow, J, Preuss, M, Sherry, A, ASME
Format: Conference item
Published: 2005