Implantation of the black diaphragm intraocular lens in congenital and traumatic aniridia.
OBJECTIVE: To evaluate the biometry accuracy, visual outcomes, and long-term changes in intraocular pressure after implantation of the black diaphragm intraocular (BDI) lens in cases of aniridia. DESIGN: Retrospective, interventional case series. PARTICIPANTS: Forty eyes of 35 patients with aniridia...