The integration of liquid and solid muon absorbers into a focusing magnet of a muon cooling channel
This report describes how one can integrate the muon absorber with the focusing coils of a SFOFO muon cooling channel [1]. The absorber material must be a low Z material that reduces the muon momentum with minimum scattering. The best materials to use for muon ionization cooling absorbers are hydrog...