Gap-corrected thin-film permittivity and permeability measurement with a broadband coaxial line technique

A technique for measuring the high frequency broadband complex permittivity and permeability of thin films from 50 MHz up to 18 GHz without the need for a reference sample for calibration is presented. A thin film for measurement is wound into a torus and inserted into a coaxial line. As a cons...

पूर्ण विवरण

ग्रंथसूची विवरण
मुख्य लेखकों: Wang, Y, Hooper, I, Edwards, E, Grant, P
स्वरूप: Journal article
प्रकाशित: IEEE 2016