Manufacture and initial thermo-fluid measurements on a heat sink module for potential applications in a DEMO

The necessity to handle heat loads in the MW/m2 range has become increasingly prevalent in a number of industries. Termed high-heat flux cooling, some of the most challenging conditions in this field occur at the first wall and divertor regions of a fusion tokamak. Steady-state heat fluxes here may...

Full description

Bibliographic Details
Main Authors: Nicholas, JR, Ireland, PT, Hancock, D, Robertson, D
Format: Conference item
Language:English
Published: Taylor and Francis 2017