Degradation Diagnostics for Commercial Lithium-Ion Cells Tested at −10◦C

Degradation of lithium ion (Li-ion) cells affects both performance and safety of Li-ion batteries. In order to avoid potential safety hazards, it is crucial to detect the onset and extent of critical degradation modes in commercial Li-ion cells. This work demonstrates the application of a diagnostic...

Full description

Bibliographic Details
Main Authors: Birkl, C, McTurk, E, Zekoll, S, Richter, F, Roberts, M, Bruce, P, Howey, D
Format: Journal article
Published: Electrochemical Society 2017