Integrating Philips' extreme UV source in the alpha-tools

The paper describes recent progress in the development of the Philips's EUV source. Progress has been realized at many frontiers: Integration studies of the source into a scanner have primarily been studied on the Xe source because it has a high degree of maturity. We report on integration with...

Full description

Bibliographic Details
Main Authors: Pankert, J, Apetz, R, Bergmann, K, Derra, G, Janssen, M, Jonkers, J, Klein, J, Krucken, T, List, A, Loeken, M, Metzmacher, C, Neff, W, Probst, S, Prummer, R, Rosier, O, Seiwert, S, Siemons, G, Vaudrevange, D, Wagemann, D, Weber, A, Zink, P, Zitzen, O
Format: Conference item
Published: 2005
_version_ 1826290819170041856
author Pankert, J
Apetz, R
Bergmann, K
Derra, G
Janssen, M
Jonkers, J
Klein, J
Krucken, T
List, A
Loeken, M
Metzmacher, C
Neff, W
Probst, S
Prummer, R
Rosier, O
Seiwert, S
Siemons, G
Vaudrevange, D
Wagemann, D
Weber, A
Zink, P
Zitzen, O
author_facet Pankert, J
Apetz, R
Bergmann, K
Derra, G
Janssen, M
Jonkers, J
Klein, J
Krucken, T
List, A
Loeken, M
Metzmacher, C
Neff, W
Probst, S
Prummer, R
Rosier, O
Seiwert, S
Siemons, G
Vaudrevange, D
Wagemann, D
Weber, A
Zink, P
Zitzen, O
author_sort Pankert, J
collection OXFORD
description The paper describes recent progress in the development of the Philips's EUV source. Progress has been realized at many frontiers: Integration studies of the source into a scanner have primarily been studied on the Xe source because it has a high degree of maturity. We report on integration with a collector, associated collector lifetime and optical characteristics. Collector lifetime in excess of 1 bln shots could be demonstrated. Next, an active dose control system was developed and tested on the Xe lamp. Resulting dose stability data are less than 0.2% for an exposure window of 100 pulses. The second part of the paper reports on progress in the development of the Philips' Sri source. First, the details of the concept are described. It is based on a Laser triggered vacuum arc, which is an extension with respect to previous designs. The source is furbished with rotating electrodes that are covered with a Sri film that is constantly regenerated. Hence by the very design of the source, it is scalable to very high power levels, and moreover has fundamentally solved the notorious problem of electrode erosion. Power values of 260 W in 2 pi sr are reported, along with a stable, long life operation of the lamp. The paper also addresses the problem of debris generation and mitigation of the Sn-source. The problem is attacked by a combined strategy of protection of the collector by traditional means (e.g. fields, foiltraps,...), and by designing the gas atmosphere according to the principles of the well known halogen cycles in incandescent lamps. These principles have been studied in the Lighting industry for decades and rely on the excessively high vapor pressures of metal halides. Transferred to the Sri source, it allows pumping away tin residues that would otherwise irreversibly deposit on the collector.
first_indexed 2024-03-07T02:50:02Z
format Conference item
id oxford-uuid:ad5f3121-0aa1-4d7e-b5d6-2774a0b172e8
institution University of Oxford
last_indexed 2024-03-07T02:50:02Z
publishDate 2005
record_format dspace
spelling oxford-uuid:ad5f3121-0aa1-4d7e-b5d6-2774a0b172e82022-03-27T03:35:21ZIntegrating Philips' extreme UV source in the alpha-toolsConference itemhttp://purl.org/coar/resource_type/c_5794uuid:ad5f3121-0aa1-4d7e-b5d6-2774a0b172e8Symplectic Elements at Oxford2005Pankert, JApetz, RBergmann, KDerra, GJanssen, MJonkers, JKlein, JKrucken, TList, ALoeken, MMetzmacher, CNeff, WProbst, SPrummer, RRosier, OSeiwert, SSiemons, GVaudrevange, DWagemann, DWeber, AZink, PZitzen, OThe paper describes recent progress in the development of the Philips's EUV source. Progress has been realized at many frontiers: Integration studies of the source into a scanner have primarily been studied on the Xe source because it has a high degree of maturity. We report on integration with a collector, associated collector lifetime and optical characteristics. Collector lifetime in excess of 1 bln shots could be demonstrated. Next, an active dose control system was developed and tested on the Xe lamp. Resulting dose stability data are less than 0.2% for an exposure window of 100 pulses. The second part of the paper reports on progress in the development of the Philips' Sri source. First, the details of the concept are described. It is based on a Laser triggered vacuum arc, which is an extension with respect to previous designs. The source is furbished with rotating electrodes that are covered with a Sri film that is constantly regenerated. Hence by the very design of the source, it is scalable to very high power levels, and moreover has fundamentally solved the notorious problem of electrode erosion. Power values of 260 W in 2 pi sr are reported, along with a stable, long life operation of the lamp. The paper also addresses the problem of debris generation and mitigation of the Sn-source. The problem is attacked by a combined strategy of protection of the collector by traditional means (e.g. fields, foiltraps,...), and by designing the gas atmosphere according to the principles of the well known halogen cycles in incandescent lamps. These principles have been studied in the Lighting industry for decades and rely on the excessively high vapor pressures of metal halides. Transferred to the Sri source, it allows pumping away tin residues that would otherwise irreversibly deposit on the collector.
spellingShingle Pankert, J
Apetz, R
Bergmann, K
Derra, G
Janssen, M
Jonkers, J
Klein, J
Krucken, T
List, A
Loeken, M
Metzmacher, C
Neff, W
Probst, S
Prummer, R
Rosier, O
Seiwert, S
Siemons, G
Vaudrevange, D
Wagemann, D
Weber, A
Zink, P
Zitzen, O
Integrating Philips' extreme UV source in the alpha-tools
title Integrating Philips' extreme UV source in the alpha-tools
title_full Integrating Philips' extreme UV source in the alpha-tools
title_fullStr Integrating Philips' extreme UV source in the alpha-tools
title_full_unstemmed Integrating Philips' extreme UV source in the alpha-tools
title_short Integrating Philips' extreme UV source in the alpha-tools
title_sort integrating philips extreme uv source in the alpha tools
work_keys_str_mv AT pankertj integratingphilipsextremeuvsourceinthealphatools
AT apetzr integratingphilipsextremeuvsourceinthealphatools
AT bergmannk integratingphilipsextremeuvsourceinthealphatools
AT derrag integratingphilipsextremeuvsourceinthealphatools
AT janssenm integratingphilipsextremeuvsourceinthealphatools
AT jonkersj integratingphilipsextremeuvsourceinthealphatools
AT kleinj integratingphilipsextremeuvsourceinthealphatools
AT kruckent integratingphilipsextremeuvsourceinthealphatools
AT lista integratingphilipsextremeuvsourceinthealphatools
AT loekenm integratingphilipsextremeuvsourceinthealphatools
AT metzmacherc integratingphilipsextremeuvsourceinthealphatools
AT neffw integratingphilipsextremeuvsourceinthealphatools
AT probsts integratingphilipsextremeuvsourceinthealphatools
AT prummerr integratingphilipsextremeuvsourceinthealphatools
AT rosiero integratingphilipsextremeuvsourceinthealphatools
AT seiwerts integratingphilipsextremeuvsourceinthealphatools
AT siemonsg integratingphilipsextremeuvsourceinthealphatools
AT vaudrevanged integratingphilipsextremeuvsourceinthealphatools
AT wagemannd integratingphilipsextremeuvsourceinthealphatools
AT webera integratingphilipsextremeuvsourceinthealphatools
AT zinkp integratingphilipsextremeuvsourceinthealphatools
AT zitzeno integratingphilipsextremeuvsourceinthealphatools