Annular dump diffuser and deswirl system for back-pressure control in engine-scale transonic annular cascade

<p>A common requirement for turbomachinery testing facilities is the ability to independently control Mach number and Reynolds number. In practice, this means independent control of the inlet total pressure and exit static pressure in a test facility. In this paper, we present a solution to th...

पूर्ण विवरण

ग्रंथसूची विवरण
मुख्य लेखकों: Michaud, M, Ornano, F, Povey, T
स्वरूप: Journal article
भाषा:English
प्रकाशित: American Society of Mechanical Engineers 2022