An analysis of the use of electrical power measurements for process control in large-scale stirred vessels
The mechanical power that is transferred to a liquid via the shaft of an agitator is obtained from a measurement of the electrical power flowing into the electric motor within an accuracy of less than 5%. The accuracy obtained is limited by the calibration procedure. As the implementation of an elec...
Main Authors: | , , , |
---|---|
Format: | Journal article |
Language: | English |
Published: |
2000
|