Electronic identification systems reduce the number of wrong components transfused
<br><strong>Background: </strong>Errors in hospital transfusion may cause wrong (blood) components to be transfused. This study assessed the value of electronic identification systems (EISs) in reducing wrong component transfusions (WCTs).</br> <br><strong>Method...
Autori principali: | Murphy, MF, Addison, J, Poles, D, Dhiman, P, Bolton-Maggs, P |
---|---|