Time-resolved measurements of surface spin-wave pulses at millikelvin temperatures
We experimentally investigate the propagation of pulsed magnetostatic surface spin-wave (magnon) signals in an yttrium iron garnet (YIG) waveguide at millikelvin temperatures. Our measurements are performed in a dilution refrigerator at microwave frequencies. The excellent signal-to-noise ratio affo...
Main Authors: | , , |
---|---|
Format: | Journal article |
Published: |
American Physical Society
2018
|