Simplifying four-strand flexor tendon repair using double-stranded suture: a comparative ex vivo study on tensile strength and bulking

We have compared a simple four-strand flexor tendon repair, the single cross-stitch locked repair using a double-stranded suture (dsSCL) against two other four-strand repairs: the Pennington modified Kessler with double-stranded suture (dsPMK); and the cruciate cross-stitch locked repair with single...

Cur síos iomlán

Sonraí bibleagrafaíochta
Príomhchruthaitheoirí: Low, T.H., Ahmad, Tunku Sara, Ng, E.S.
Formáid: Alt
Foilsithe / Cruthaithe: SAGE Publications (UK and US) 2012
Ábhair: