4D characterisation of void nucleation, void growth and void coalescence using advanced void tracking algorithm on in situ X-ray tomographic data

An advanced tracking algorithm based upon 4D X-ray tomographic data was developed to enable a more robust and full field approach to ductile damage characterisation. By following each individual void, the three ductile damage mechanisms (void nucleation, void growth and void coalescence) could be se...