Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm

A person who has severe hand tremor will have difficulty in doing specific tasks such as eating, combing or holding any objects. Currently, there is no medication that can cure the tremor. Thus, this study proposes the active tremor control, in which an intelligent controller is applied to suppress...

Full description

Bibliographic Details
Main Authors: As'arry, Azizan, Rezali, Khairil Anas Md, Jalil, Nawal Aswan Abdul, Samin, Razali, Zulkefli, Zamir Aimaduddin, Zain, Mohd Zarhamdy Md.
Format: Article
Language:English
Published: Inderscience Publisher 2017
Online Access:http://psasir.upm.edu.my/id/eprint/63611/1/Tremor%20suppression%20for%204-DOFs%20biodynamic%20hand%20model%20using%20genetic%20algorithm.pdf
_version_ 1825932630854467584
author As'arry, Azizan
Rezali, Khairil Anas Md
Jalil, Nawal Aswan Abdul
Samin, Razali
Zulkefli, Zamir Aimaduddin
Zain, Mohd Zarhamdy Md.
author_facet As'arry, Azizan
Rezali, Khairil Anas Md
Jalil, Nawal Aswan Abdul
Samin, Razali
Zulkefli, Zamir Aimaduddin
Zain, Mohd Zarhamdy Md.
author_sort As'arry, Azizan
collection UPM
description A person who has severe hand tremor will have difficulty in doing specific tasks such as eating, combing or holding any objects. Currently, there is no medication that can cure the tremor. Thus, this study proposes the active tremor control, in which an intelligent controller is applied to suppress the hand tremor. The main objective is to optimise the proportional-integral (PI) controller using genetic algorithm (GA). A linear voice coil actuator (LVCA) is applied onto a four degree of freedom (4-DOF) human hand model represented in state space. The findings of the study demonstrate that the PI controller optimised by GA gives excellent performance in reducing the tremor error. Based on the frequency evaluation, the PI controller performance was roughly around 84% in reducing the peak of simulated hand tremor. The outcomes provide an important contribution towards achieving novel methods in suppressing hand tremor model by means of intelligent control.
first_indexed 2024-03-06T09:44:59Z
format Article
id upm.eprints-63611
institution Universiti Putra Malaysia
language English
last_indexed 2024-03-06T09:44:59Z
publishDate 2017
publisher Inderscience Publisher
record_format dspace
spelling upm.eprints-636112018-11-07T03:23:19Z http://psasir.upm.edu.my/id/eprint/63611/ Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm As'arry, Azizan Rezali, Khairil Anas Md Jalil, Nawal Aswan Abdul Samin, Razali Zulkefli, Zamir Aimaduddin Zain, Mohd Zarhamdy Md. A person who has severe hand tremor will have difficulty in doing specific tasks such as eating, combing or holding any objects. Currently, there is no medication that can cure the tremor. Thus, this study proposes the active tremor control, in which an intelligent controller is applied to suppress the hand tremor. The main objective is to optimise the proportional-integral (PI) controller using genetic algorithm (GA). A linear voice coil actuator (LVCA) is applied onto a four degree of freedom (4-DOF) human hand model represented in state space. The findings of the study demonstrate that the PI controller optimised by GA gives excellent performance in reducing the tremor error. Based on the frequency evaluation, the PI controller performance was roughly around 84% in reducing the peak of simulated hand tremor. The outcomes provide an important contribution towards achieving novel methods in suppressing hand tremor model by means of intelligent control. Inderscience Publisher 2017 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/63611/1/Tremor%20suppression%20for%204-DOFs%20biodynamic%20hand%20model%20using%20genetic%20algorithm.pdf As'arry, Azizan and Rezali, Khairil Anas Md and Jalil, Nawal Aswan Abdul and Samin, Razali and Zulkefli, Zamir Aimaduddin and Zain, Mohd Zarhamdy Md. (2017) Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm. International Journal of Advanced Mechatronic Systems, 7 (3). 151 - 157. ISSN 1756-8412; ESSN: 1756-8420 http://www.inderscience.com/info/inarticle.php?artid=86207 10.1504/IJAMECHS.2017.10007355
spellingShingle As'arry, Azizan
Rezali, Khairil Anas Md
Jalil, Nawal Aswan Abdul
Samin, Razali
Zulkefli, Zamir Aimaduddin
Zain, Mohd Zarhamdy Md.
Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm
title Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm
title_full Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm
title_fullStr Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm
title_full_unstemmed Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm
title_short Tremor suppression for 4-DOFs biodynamic hand model using genetic algorithm
title_sort tremor suppression for 4 dofs biodynamic hand model using genetic algorithm
url http://psasir.upm.edu.my/id/eprint/63611/1/Tremor%20suppression%20for%204-DOFs%20biodynamic%20hand%20model%20using%20genetic%20algorithm.pdf
work_keys_str_mv AT asarryazizan tremorsuppressionfor4dofsbiodynamichandmodelusinggeneticalgorithm
AT rezalikhairilanasmd tremorsuppressionfor4dofsbiodynamichandmodelusinggeneticalgorithm
AT jalilnawalaswanabdul tremorsuppressionfor4dofsbiodynamichandmodelusinggeneticalgorithm
AT saminrazali tremorsuppressionfor4dofsbiodynamichandmodelusinggeneticalgorithm
AT zulkeflizamiraimaduddin tremorsuppressionfor4dofsbiodynamichandmodelusinggeneticalgorithm
AT zainmohdzarhamdymd tremorsuppressionfor4dofsbiodynamichandmodelusinggeneticalgorithm