Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction
In this paper, a new reference current generation method is proposed for effective harmonics mitigation and reactive power compensation of three-level neutral-point diode clamped inverter-based shunt active power filter (SAPF) under nonideal grid voltage conditions. The proposed method is named as d...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Electrical and Electronics Engineers (IEEE)
2018
|
Online Access: | http://psasir.upm.edu.my/id/eprint/75141/1/Operation%20of%20three-level%20inverter-based%20shunt%20active%20power%20filter%20under%20nonideal%20grid%20voltage%20conditions%20with%20dual%20fundamental%20component%20extraction.pdf |
_version_ | 1825950418011684864 |
---|---|
author | Yap, Hoon Mohd Radzi, Mohd Amran Hassan, Mohd Khair Mailah, Nashiren Farzilah |
author_facet | Yap, Hoon Mohd Radzi, Mohd Amran Hassan, Mohd Khair Mailah, Nashiren Farzilah |
author_sort | Yap, Hoon |
collection | UPM |
description | In this paper, a new reference current generation method is proposed for effective harmonics mitigation and reactive power compensation of three-level neutral-point diode clamped inverter-based shunt active power filter (SAPF) under nonideal grid voltage conditions. The proposed method is named as dual fundamental component extraction algorithm. In operation, the proposed algorithm extracts at the same time, the desired fundamental current and voltage components for generating reference current and synchronization phases, respectively. As a result, the proposed algorithm is able to generate reference current that ensures in phase operation of SAPF with the operating power system, without depending on any phase-locked loop elements. Besides, the proposed algorithm employs self-tuning filter (STF) for accurate computation of the fundamental components. Design concept and effectiveness of the proposed algorithm are thoroughly studied and evaluated in MATLAB-Simulink. Additionally, a laboratory prototype utilizing TMS320F28335 digital signal processor is built to validate its feasibility. Encouraging findings obtained from both simulation and experimental works demonstrate effectiveness of the proposed algorithm under both ideal and nonideal grid voltage conditions. |
first_indexed | 2024-03-06T10:14:17Z |
format | Article |
id | upm.eprints-75141 |
institution | Universiti Putra Malaysia |
language | English |
last_indexed | 2024-03-06T10:14:17Z |
publishDate | 2018 |
publisher | Institute of Electrical and Electronics Engineers (IEEE) |
record_format | dspace |
spelling | upm.eprints-751412020-04-20T17:54:55Z http://psasir.upm.edu.my/id/eprint/75141/ Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction Yap, Hoon Mohd Radzi, Mohd Amran Hassan, Mohd Khair Mailah, Nashiren Farzilah In this paper, a new reference current generation method is proposed for effective harmonics mitigation and reactive power compensation of three-level neutral-point diode clamped inverter-based shunt active power filter (SAPF) under nonideal grid voltage conditions. The proposed method is named as dual fundamental component extraction algorithm. In operation, the proposed algorithm extracts at the same time, the desired fundamental current and voltage components for generating reference current and synchronization phases, respectively. As a result, the proposed algorithm is able to generate reference current that ensures in phase operation of SAPF with the operating power system, without depending on any phase-locked loop elements. Besides, the proposed algorithm employs self-tuning filter (STF) for accurate computation of the fundamental components. Design concept and effectiveness of the proposed algorithm are thoroughly studied and evaluated in MATLAB-Simulink. Additionally, a laboratory prototype utilizing TMS320F28335 digital signal processor is built to validate its feasibility. Encouraging findings obtained from both simulation and experimental works demonstrate effectiveness of the proposed algorithm under both ideal and nonideal grid voltage conditions. Institute of Electrical and Electronics Engineers (IEEE) 2018 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/75141/1/Operation%20of%20three-level%20inverter-based%20shunt%20active%20power%20filter%20under%20nonideal%20grid%20voltage%20conditions%20with%20dual%20fundamental%20component%20extraction.pdf Yap, Hoon and Mohd Radzi, Mohd Amran and Hassan, Mohd Khair and Mailah, Nashiren Farzilah (2018) Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction. IEEE Transactions on Power Electronics, 33 (9). 7558 - 7570. ISSN 0885-8993; ESSN: 1941-0107 10.1109/TPEL.2017.2766268 |
spellingShingle | Yap, Hoon Mohd Radzi, Mohd Amran Hassan, Mohd Khair Mailah, Nashiren Farzilah Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction |
title | Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction |
title_full | Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction |
title_fullStr | Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction |
title_full_unstemmed | Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction |
title_short | Operation of three-level inverter-based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction |
title_sort | operation of three level inverter based shunt active power filter under nonideal grid voltage conditions with dual fundamental component extraction |
url | http://psasir.upm.edu.my/id/eprint/75141/1/Operation%20of%20three-level%20inverter-based%20shunt%20active%20power%20filter%20under%20nonideal%20grid%20voltage%20conditions%20with%20dual%20fundamental%20component%20extraction.pdf |
work_keys_str_mv | AT yaphoon operationofthreelevelinverterbasedshuntactivepowerfilterundernonidealgridvoltageconditionswithdualfundamentalcomponentextraction AT mohdradzimohdamran operationofthreelevelinverterbasedshuntactivepowerfilterundernonidealgridvoltageconditionswithdualfundamentalcomponentextraction AT hassanmohdkhair operationofthreelevelinverterbasedshuntactivepowerfilterundernonidealgridvoltageconditionswithdualfundamentalcomponentextraction AT mailahnashirenfarzilah operationofthreelevelinverterbasedshuntactivepowerfilterundernonidealgridvoltageconditionswithdualfundamentalcomponentextraction |