Lightning induced surges on an unenergized test overhead telecommunication subscriber line
Voltages induced on a test unenergized 1.8 km straight overhead telecommunication subscriber line by nearby lightning return stroke to ground is presented by solving transmission line coupling equations using time domain approach in combination with the numerical calculation of horizontal and vertic...