Screening of combined zeolite-ozone system for phenol and COD removal

In this study, four zeolites in H-form (HZSM-5, H-Beta, H-Mordenite, and H-USY) were tested at different operating conditions for removal of phenol and COD by ozonation. The process variables include concentration of phenol in solution, ozonated airflow rates, pH of solution, temperature, and reacti...

Full description

Bibliographic Details
Main Authors: Saidina Amin, Nor Aishah, Akhtar, Javaid, Rai, H. K.
Format: Article
Published: Elsevier B.V. 2010
Subjects: