Experimental investigation of retrofitted extended end-plate connections
A series of retrofitted extended end-plate connections have been tested experimentally and evaluated using the component method specified in Eurocode 3. The component method decomposed the end-plate connection into several components, including the tension zone, compression zone, vertical and horizo...
Main Authors: | , , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
2013
|
Subjects: |