Empirical correlations for sizing adiabatic capillary tube using LPG as refrigerant in split-type air-conditioner

This paper presents correlations for sizing adiabatic capillary tubes which serves as an expansion device in split-type air-conditioner with LPG, novel hydrocarbon (HC) mixtures of butane (HC600) and propane (HC290) as refrigerant. A homogenous two-phase flow model developed by the authors and also...

Full description

Bibliographic Details
Main Authors: Sulaimon, Shodiya, Abdul Aziz, Azhar, Darus, Amer Nordin, Nasution, Henry
Format: Article
Published: Trans Tech Publications, Switzerland 2014
Subjects: