Microbiologically induced corrosion monitoring using open-circuit potential (OCP) measurements
This study investigates how sulfate-reducing bacteria (SRB) influence the process of microbiologically induced corrosion (MIC) of carbon steel by measuring corrosion potential using open-circuit potential (OCP) measurements. MIC is mainly influenced by D. Vulgaris, formerly known as D. Desulfuricans...
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
2015
|
Subjects: |