Development of hand-arm model rig for tremor excitation
This paper describes the development of a handarm model rig to simulate human tremor behaviour. The experimental rig is designed as an apparatus to induce vibration along a hand-arm model. An Intra Vernacular (IV) Training arm is used as the handarm model. Displacement and acceleration behaviour at...
Main Authors: | , , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2008
|
Subjects: | |
Online Access: | http://eprints.utm.my/7654/1/Mailah_Musa_2008_Development_Hand-arm_Model_Rig_Tremor.pdf |