Real-time implementation of feed rate active force control of a syringe fluid dispenser

For precise application, it is imperative to provide accurate and stable performance. The feed flow rate of a syringe fluid dispensing system is regulated through a Proportional-Integral-Derivative (PID) and Active Force Control (AFC) control scheme that was actuated using a DC servo motor consideri...

Full description

Bibliographic Details
Main Authors: Sharif, S. K. B., Mailah, M.
Format: Article
Published: Penerbit UTM Press 2017