Diagnosis of reduction gear failures of a power generation gas turbine due to excessive pipe strain

This paper presents a case study in diagnosing a frequent fatigue failure of a reduction gear used in power generation in oil and gas industry. The reduction gear was connected to a main oil pump (MOP) via a coupling which in turn draw oil from oil reservoir via a series of connecting pipes. An init...

Full description

Bibliographic Details
Main Authors: Lim, Meng Hee, Leong, Mohd. Salman @ Yew Mun, Hui, Kar Hoou, Ooi, Ching Sheng
Format: Conference or Workshop Item
Published: 2018
Subjects: